What is the maintenance and inspection of a 200 ton chiller?
What is the maintenance and inspection of a 200 ton chiller?
1. Check the stability of voltage and current
2. Regularly inspect the compressor
The necessary acceptance tests for the chiller should be carried out in accordance with the principle of first air tightness test, then vacuum test, first sub item test, and then overall test
3. Regular cleaning
In addition to checking the technical performance of the chiller, pay attention to protecting the clean appearance of the cooler and the cleanliness of the work site. When the air-cooled chiller operates for 6 months, the entire system, such as pipelines, filters, condensers, fans, etc., should be cleaned, especially the fans. Like our commonly used fans, they are covered in dust, which affects heat dissipation, thus directly reducing cooling efficiency.
4. Regularly inspect instruments
The temperature controller is out of control, replace the temperature controller, high voltage fault, poor heat dissipation, the radiator is too dirty, the air cannot be cleaned well, improve the ventilation condition, the Computer fan does not work, check whether the fan motor is burned out, repair or replace the motor, the high voltage engine is damaged, and replace the high voltage engine.
Daily maintenance:
① Clean the surface of the unit.
③ Check whether the three-phase voltage of the power supply is normal at 380v.
④ Check whether the oil heater works normally when it is powered on (the oil temperature shall be kept at 25~30 ℃ during standby).
⑤ Check for water and oil leakage in all parts of the body.
⑥ Check whether the temperature control probe is normal.
⑦ Check whether all parameters during the operation of the unit are within the standard values (see the host manual for specific parameters).
⑧ Check whether the energy regulating mechanism operates flexibly during the operation of the unit (i.e. loading and unloading solenoid valves, slide valve mechanisms).
⑨ Check whether the sound of the unit is normal during normal operation.
⑩ Check whether the temperature of the unit during normal operation is normal (including main motor, compressor, exhaust temperature, oil temperature, etc.).
Related recommendations
How important is insulation treatment for laboratory chiller?
709How important is insulation treatment for laboratory chiller? For chillers, if operated at high temperatures, a large amount of cold air from industrial chillers may be severely lost. A...
View detailscool & heat
144Cool & Heat: Balancing Temperature for Comfort and Efficiency Temperature management is a fundamental aspect of creating comfortable and productive environments. Whether it's sweltering sum...
View detailsgerman chiller manufacturer
85Historical BackgroundGermany has a long - standing reputation for excellence in manufacturing, and the chiller - manufacturing sector is no exception. The roots of German chiller manufacturing can...
View detailsHow to judge the energy-saving effect of process water chillers?
695How to judge the energy-saving effect of process water chillers? Firstly, it is important to understand the concept of energy efficiency ratio of process water coolers. When purchasing ...
View details
HelloPlease log in