SEARCH WHAT YOU WANT
Enter keyword or product model

TES -60℃~+200℃

Temperature Control System

For fuel oil test

· Media Temperature Control Accuracy ±0.5℃

· Fuel Oil Temperature Accuracy ±2℃

· Heating Power 15kW~60kW

· Cooling Capacity 3kW~60kW

· Power 28kW~102kW

· Refrigerant R404A R23

· Type Positive Pressure/Isolation Explosion-proof

Appearance Structure

Product Features

  • Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm
  • With DANFOSS/High pressure Plate Heat Exchanger
  • Type W is water cooled
  • Water-cooled condenser Casing heat exchanger (Paris / Shen’s)
  • Customizable isolation explosion proof (EXdIIBT4);

Main Parameters

 ModelTES-6A15WPEX
TES-6A15WDEX
TES-6A25WPEX
TES-6A25WDEX
TES-6A45WPEX
TES-6A45WDEX
TES-6A60WPEX
TES-6A60WDEX
Temp Range-60℃~200℃-60℃~200℃-60℃~200℃-60℃~200℃
Heating Power15kW25kW45kW60kW
Refrigerating Output200℃15kW25kW45kW60kW
100℃15kW25kW45kW60kW
20℃15kW25kW45kW60kW
0℃15kW25kW45kW60kW
-20℃12kW20kW35kW48kW
-40℃8kW14kW25kW35kW
-50℃5kW8kW15kW25kW
-55℃3kW5kW9kW15kW
Temp Control Accuracy Of Heat Conduction Medium±0.5℃
Fuel Temp Control Accuracy±2℃ Steady State
System Pressure DisplayPressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen.
ControllerSiemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm.
Temperature ControlTemperature Control Mode for outlet of Heat conduction medium;
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control).
Communicating ProtocolEthernet Interface TCP/IP Protocol
Internal Temp FeedbackEquipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, positive pressure chamber ambient temperature, compressor suction temperature, cooling water temperature (water-cooling equipment is configured).
External Access Temp FeedbackPT100 or 4~20mA or communication given
Cascade Control TimeThe temperature difference between the outlet temperature and the external temperature sensor can be set and controlled;
TempDifference Control FunctionThe temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system).
Closed-cycle SystemThe whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature.
Heating PowerThe maximum heating output power of the system (according to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system;
Heating power 10kW adopts regulator, heating power output control adopts 4~20mA linear control.
Refrigerating CapacityRefers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures.
High Temp Cooling ModuleFrom the high temperature 200 degrees cooling module.
Circulating pump flow maxMagnetic drive pump with crown magnetic drive pump/ German brand.
110L/min 2.5BAR200L/min 2.5BAR400L/min 2.5BAR500L/min 2.5BAR
Source 380V 50HZ28kW max48kW max70kW max102kW max
Shape Size (Positive Pressure)cm135 *145*225(135+60) *145*225(185+60) *145*225(185+60) *145*225
External Dimension (Isolation)mm800*1450*18501000*1750*18501450*2050*20501450*2050*2050
Compression EngineItaly Duling semi-enclosed compressor / BiZell semi-enclosed compressor.
EvaporatorDANFOSS KAORI Plate Heat Exchanger
Refrigeration AccessoryOil separator, dry filter, thermal expansion valve, electronic expansion valve, refrigeration solenoid valve, pressure control, mirror, etc. All adopt Emerson / Danvers brand.
Operation PanelColor touch screen, temperature curve display\ EXCEL data export.
Safe GuardingWith self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
CryogenR-404A R23
Interface SizeDN32 PN10 RFDN32 PN10 RFDN40 PN10 RFDN50 PN10 RF
Water-Cooled WType W is water cooled.
Water-cooled CondenserTube type heat exchanger(Paris/Shenshi).
Cooling Water Quantity At 20℃5m3/h9m3/h15m3/h24m3/h
Shell materialCold rolled sheet spray (Standard Colour 7035)
Barotropic Explosion ProtectionPositive pressure blast proof (EXPXdmbIICT4) barotropic system must be water-cooled equipment;
Wuxi Guansub explosive proof product installation license number: PCEC-2017-B025
Barotropic System CoolingA constant temperature cooling system is installed inside the barotropic system to ensure that the ambient temperature of the barotropic chamber is below 45℃
NavarLNEYA
Expansion SystemLNEYA
Intermediate Relay\ Thermal RelayIntermediate relays, thermal relays, contactors, circuit breakers, etc., all use Schneider and other brands.
Temperature SensorTiankang
Explosion-proof HoseTu’an explosion-proof threading hose
Internal&External ControlThis\ External control mode is switchable

Accessories Details

System pressure displayThe pressure of the refrigeration system is realized by the pointer type pressure gauge (high-pressure and low-pressure).
The circulation system pressure is displayed on the touch screen by pressure sensor detection.
Temp. controlTemperature Control Mode for outlet of Heat conduction medium;
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control)
Programmable10 procedures can be developed, and each program can be composed of 40 steps
Communicating protocolEthernet Interface TCP/IP Protocol
Internal temp. feedback of equipmentEquipment heat-conducting medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (configuration of water-cooling equipment)
External access temp. feedbackPT100 or 4~20mA or communication given
String-level controlThe temperature difference between the outlet temperature and the external temperature sensor can be set and controlled;
Temp. difference control functionThe temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system).
Closed-cycle systemThe whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature.
Heating PowerThe maximum heating output power of the system (according to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system;
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control.
Cooling capacityIt refers to the ability to carry away heat at different temperatures (in the ideal state). The actual working conditions need to be considered for environmental heat dissipation. Please enlarge it properly and do well the thermal insulation measures.
Circulation pump flow, pressure maxAdopt LNEYA magnetic drive pump / Germany brand magnetic drive pump
      
Refrigeration AccessoryDanfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves)
Operation panelLNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export
Safe guardingWith self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Air-cooled typeIt adopts copper tube aluminum fin condensation method, upper air outlet type, and the condensation fan adopts German EBM axial flow fan.
SourceCustomizable 460V 60HZN 220V 60HZ three-phase
Shell materialCold rolled sheet spray (Standard Colour 7035)
Isolation explosion proofInstallation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025
Barotropic explosion protectionA custom positive pressure explosion-proof (EXPXdmbIICT4) positive pressure system must be a water-cooled device;
  Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025

Product Applications

Chip-Specific High and Low Temperature Tester In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85 °C to +200 °C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.

Recommended ProductsUsed for Reaction

loading…

已经是到最后一篇内容了!

Expand more!
1
Leave a message