TES -60℃~+200℃
Temperature Control System
For fuel oil test
· Media Temperature Control Accuracy ±0.5℃
· Fuel Oil Temperature Accuracy ±2℃
· Heating Power 15kW~60kW
· Cooling Capacity 3kW~60kW
· Power 28kW~102kW
· Refrigerant R404A R23
· Type Positive Pressure/Isolation Explosion-proof
Appearance Structure
Product Features
- Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm
- With DANFOSS/High pressure Plate Heat Exchanger
- Type W is water cooled
- Water-cooled condenser Casing heat exchanger (Paris / Shen’s)
- Customizable isolation explosion proof (EXdIIBT4);
Main Parameters
Model | TES-6A15WPEX TES-6A15WDEX | TES-6A25WPEX TES-6A25WDEX | TES-6A45WPEX TES-6A45WDEX | TES-6A60WPEX TES-6A60WDEX | |
Temp Range | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | |
Heating Power | 15kW | 25kW | 45kW | 60kW | |
Refrigerating Output | 200℃ | 15kW | 25kW | 45kW | 60kW |
100℃ | 15kW | 25kW | 45kW | 60kW | |
20℃ | 15kW | 25kW | 45kW | 60kW | |
0℃ | 15kW | 25kW | 45kW | 60kW | |
-20℃ | 12kW | 20kW | 35kW | 48kW | |
-40℃ | 8kW | 14kW | 25kW | 35kW | |
-50℃ | 5kW | 8kW | 15kW | 25kW | |
-55℃ | 3kW | 5kW | 9kW | 15kW | |
Temp Control Accuracy Of Heat Conduction Medium | ±0.5℃ | ||||
Fuel Temp Control Accuracy | ±2℃ Steady State | ||||
System Pressure Display | Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure); | ||||
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen. | |||||
Controller | Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm. | ||||
Temperature Control | Temperature Control Mode for outlet of Heat conduction medium; | ||||
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control). | |||||
Communicating Protocol | Ethernet Interface TCP/IP Protocol | ||||
Internal Temp Feedback | Equipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, positive pressure chamber ambient temperature, compressor suction temperature, cooling water temperature (water-cooling equipment is configured). | ||||
External Access Temp Feedback | PT100 or 4~20mA or communication given | ||||
Cascade Control Time | The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled; | ||||
TempDifference Control Function | The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system). | ||||
Closed-cycle System | The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature. | ||||
Heating Power | The maximum heating output power of the system (according to each model); | ||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system; | |||||
Heating power 10kW adopts regulator, heating power output control adopts 4~20mA linear control. | |||||
Refrigerating Capacity | Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures. | ||||
High Temp Cooling Module | From the high temperature 200 degrees cooling module. | ||||
Circulating pump flow max | Magnetic drive pump with crown magnetic drive pump/ German brand. | ||||
110L/min 2.5BAR | 200L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | ||
Source 380V 50HZ | 28kW max | 48kW max | 70kW max | 102kW max | |
Shape Size (Positive Pressure)cm | 135 *145*225 | (135+60) *145*225 | (185+60) *145*225 | (185+60) *145*225 | |
External Dimension (Isolation)mm | 800*1450*1850 | 1000*1750*1850 | 1450*2050*2050 | 1450*2050*2050 | |
Compression Engine | Italy Duling semi-enclosed compressor / BiZell semi-enclosed compressor. | ||||
Evaporator | DANFOSS KAORI Plate Heat Exchanger | ||||
Refrigeration Accessory | Oil separator, dry filter, thermal expansion valve, electronic expansion valve, refrigeration solenoid valve, pressure control, mirror, etc. All adopt Emerson / Danvers brand. | ||||
Operation Panel | Color touch screen, temperature curve display\ EXCEL data export. | ||||
Safe Guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | ||||
Cryogen | R-404A R23 | ||||
Interface Size | DN32 PN10 RF | DN32 PN10 RF | DN40 PN10 RF | DN50 PN10 RF | |
Water-Cooled W | Type W is water cooled. | ||||
Water-cooled Condenser | Tube type heat exchanger(Paris/Shenshi). | ||||
Cooling Water Quantity At 20℃ | 5m3/h | 9m3/h | 15m3/h | 24m3/h | |
Shell material | Cold rolled sheet spray (Standard Colour 7035) | ||||
Barotropic Explosion Protection | Positive pressure blast proof (EXPXdmbIICT4) barotropic system must be water-cooled equipment; | ||||
Wuxi Guansub explosive proof product installation license number: PCEC-2017-B025 | |||||
Barotropic System Cooling | A constant temperature cooling system is installed inside the barotropic system to ensure that the ambient temperature of the barotropic chamber is below 45℃ | ||||
Navar | LNEYA | ||||
Expansion System | LNEYA | ||||
Intermediate Relay\ Thermal Relay | Intermediate relays, thermal relays, contactors, circuit breakers, etc., all use Schneider and other brands. | ||||
Temperature Sensor | Tiankang | ||||
Explosion-proof Hose | Tu’an explosion-proof threading hose | ||||
Internal&External Control | This\ External control mode is switchable |
Accessories Details
System pressure display | The pressure of the refrigeration system is realized by the pointer type pressure gauge (high-pressure and low-pressure). | |||||
The circulation system pressure is displayed on the touch screen by pressure sensor detection. | ||||||
Temp. control | Temperature Control Mode for outlet of Heat conduction medium; | |||||
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control) | ||||||
Programmable | 10 procedures can be developed, and each program can be composed of 40 steps | |||||
Communicating protocol | Ethernet Interface TCP/IP Protocol | |||||
Internal temp. feedback of equipment | Equipment heat-conducting medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (configuration of water-cooling equipment) | |||||
External access temp. feedback | PT100 or 4~20mA or communication given | |||||
String-level control | The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled; | |||||
Temp. difference control function | The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system). | |||||
Closed-cycle system | The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature. | |||||
Heating Power | The maximum heating output power of the system (according to each model); | |||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system; | ||||||
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control. | ||||||
Cooling capacity | It refers to the ability to carry away heat at different temperatures (in the ideal state). The actual working conditions need to be considered for environmental heat dissipation. Please enlarge it properly and do well the thermal insulation measures. | |||||
Circulation pump flow, pressure max | Adopt LNEYA magnetic drive pump / Germany brand magnetic drive pump | |||||
Refrigeration Accessory | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves) | |||||
Operation panel | LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export | |||||
Safe guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | |||||
Air-cooled type | It adopts copper tube aluminum fin condensation method, upper air outlet type, and the condensation fan adopts German EBM axial flow fan. | |||||
Source | Customizable 460V 60HZN 220V 60HZ three-phase | |||||
Shell material | Cold rolled sheet spray (Standard Colour 7035) | |||||
Isolation explosion proof | Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025 | |||||
Barotropic explosion protection | A custom positive pressure explosion-proof (EXPXdmbIICT4) positive pressure system must be a water-cooled device; | |||||
Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025 |
Product Applications
Recommended ProductsUsed for Reaction
- More
YQH -75℃~-40℃
YQH -75℃~-40℃ Used in gas condensation and liquefaction recovery. VOCS gas or other electronic gases are connected to the equipment through an induced draft fan, and are liquefied, captured and separated into a collection tank by…