How to prevent the compression ratio of cryo chiller from being too high?
How to prevent the compression ratio of cryo chiller from being too high?
1. It should be considered to choose appropriate refrigerant to control the compression ratio of industrial chillers.
2. Industrial chillers should be checked for blockages. If there are blockages, it is recommended to replace the filter to prevent the generation of impurities and prevent pipeline and valve blockages. Another issue is that insufficient refrigerant leads to suction pressure, and high suction pressure can lead to problems such as high compression ratio and exhaust temperature.
3. It is also possible to perform separate additional cooling on the compressor, which can solve the problem of high exhaust pressure and temperature caused by high compression ratio in industrial chillers.
How to control the refrigeration compression ratio of a refrigerator?
Control the evaporator outlet temperature: By controlling the evaporator outlet temperature, the temperature and pressure of the refrigerant can be controlled, thereby controlling the refrigeration compression ratio of the refrigerator.
Adjusting the refrigerant flow rate: By adjusting the refrigerant flow rate, the pressure and temperature of the refrigerant in the evaporator and condenser can be controlled, thereby controlling the refrigeration compression ratio of the refrigerator.
Installing a throttling device: By installing a throttling device, the refrigerant flow can be controlled, thereby controlling the refrigeration compression ratio of the refrigerator.
Protective measures during operation of chillers
Regularly check the compressor: Regularly check the operating status and compression ratio of the compressor, and promptly handle any problems found to avoid compressor failures caused by high compression ratios.
Regular refrigerant replacement: Regularly replace the refrigerant to avoid refrigerant aging and pollution, which can affect the refrigeration effect and operating quality of the chiller.
Installation of pressure protection device: By installing a pressure protection device, the pressure changes in the chiller can be monitored. When the pressure is abnormal, it automatically shuts down to avoid damage to the chiller and the occurrence of personnel safety accidents.
Regular cleaning and maintenance of condensers and evaporators: Regularly clean and maintain condensers and evaporators to ensure their surfaces are clean, capable of sufficient heat transfer, and to avoid malfunctions caused by excessively high refrigeration compression ratios of the refrigerator.
Related recommendations
Advantages of laboratory low-temperature circulators
398Advantages of laboratory low-temperature circulators The laboratory low-temperature circulator can simultaneously provide constant temperature and current refrigeration, heating, and ...
View detailsWhat if the compressor of the 2 ton water chiller cannot start?
442What if the compressor of the 2 ton water chiller cannot start? The chiller compressor cannot be started, which can be investigated based on the following clues Firstly, check th...
View detailsWhat environmental factors should be considered when using a 5 ton water chiller?
415What environmental factors should be considered when using a 5 ton water chiller? 1. If the environment in which a company uses a chiller is poor and the chiller needs to run for a rela...
View detailsWhat is the starting sequence flow of the 30 ton chiller?
406What is the starting sequence flow of the 30 ton chiller? (1) Confirm whether the status of each relevant valve in the unit meets the requirements of this specification. Power the elect...
View details
HelloPlease log in