What environmental usage requirements does industrial chiller machine meet?
What environmental usage requirements does industrial chiller machine meet?
1. Choose an installation environment with high security.
Due to the high temperature phenomenon generated during the operation of industrial refrigerators, it is necessary to stay away from various flammable and explosive substances, in order to improve the operational efficiency of industrial refrigerators. Moreover, many environments with high radiation levels pose significant risks to chillers, and it is necessary to choose a suitable installation environment to extend the service life of industrial chillers
2. Choose an installation environment with good lighting.
The maintenance and upkeep of industrial refrigerators is essential, so in order to ensure good maintenance visibility in the later stage, it is necessary to choose a place with good lighting and brightness, so that staff can carry out inspection, maintenance, and upkeep work in the later stage.
3. Choose an installation environment with low ambient temperature and good ventilation.
During the use of industrial refrigerators, a large amount of heat is generated. To maintain stable performance of industrial refrigerators, it is necessary to choose a place with lower temperature and better ventilation for installation, so that the cold water can dissipate heat in a timely manner. Especially for air-cooled chillers, air circulation has a significant impact on improving the overall working efficiency of the chiller.
Try to keep the room temperature below 40 ℃ and ensure good ventilation. If the temperature is below 40 ℃, the relative humidity of the environment must be below 90%. Do not install or store outdoors or outdoors.
Related recommendations
How to reduce vibration and noise in air cooled water chiller system?
422How to reduce vibration and noise in air cooled water chiller system? 1. The on-site rotor dynamic balance method for air-cooled chiller compressors reduces direct current vibration. ...
View detailsHow to deal with excessive noise in air cooled water chiller?
412How to deal with excessive noise in air cooled water chiller? Excessive noise in air-cooled chillers may be caused by the following reasons: unreasonable unit design, equipment aging, c...
View detailsWhat happens if there is too much refrigerant added to the low temp chiller?
442What happens if there is too much refrigerant added to the low temp chiller? 1. The pressure is too high. The addition of excessive refrigerant can lead to an increase in pressure, whic...
View detailsWhat factors are related to the cooling effect of a 50 ton chiller?
458What factors are related to the cooling effect of a 50 ton chiller? 1. Insufficient refrigerant Solution: It is necessary to supplement sufficient refrigerant and maintain a pres...
View details