AIR COOLED CHILLERS
Note: Air Cooled Chillers can be customized explosion-proof.
Air cooled chillers use shell and tube evaporators to exchange heat between water and refrigerant. The refrigerant system absorbs the heat in the water. After cooling the water, the heat is brought to the condenser through the compressor, and then dissipated to the outside air by the cooling fan.
Characteristics of Air-cooled Chillers:
1.The air-cooled chiller does not need to be connected to a cooling tower, and is suitable for environments with poor impurities. (Impurities are easily mixed in the cold water tower, and the dust will cause the cooling water circulation circuit to be blocked, resulting in a decrease in cooling capacity).
2. Air-cooled chillers are most suitable for areas with poor water quality, which can save other accessories such as cold water towers.
3. The use of large-capacity condenser makes it easier and more convenient to operate.
4.The floor space is reduced to a greater extent, and the installation is very convenient.
5. The air-cooled chiller adopts the design of the upper air outlet.
6. Temperature Control Range -152℃~250℃
Ultra-low Temperature For Refrigerated
Model | Cooling Capacity | Circulation Pump | Capacity of Liquid Storage | Power 220V 380V |
LT -45℃~30℃ | 0.4KW~12KW | 20L/min0.7BAR~75L/min1BAR | 15L~80L | 1.6kW~8kW |
LT -60℃~-20℃ | 0.4KW~7.2KW | 20L/min0.7BAR~75L/min1BAR | 15L~60L | 2.5kW~9kW |
LT -80℃~-20℃ | 0.2KW~7.2KW | 20L/min0.7BAR~75L/min1BAR | 15L~60L | 3kW~11.5kW |
LX -25℃~30℃ | 0.8KW~38KW | 20L/min1.5BAR~250/min2.5BAR | 15L~300L | 1.5kW~17kW |
High & Low Temperature For Reaction
Model | Cooling Capacity | Heating Power | Circulation Pump | Power 220V 380V |
SUNDI -10℃~200℃ | 1.5kW~15kW | 2.5kW~15kW | 20L/min 2bar~75L/min 2.5bar | 3.6kW~20kW |
SUNDI -25℃~200℃ | 1kW~200kW | 2.5kW~200kW | 20L/min 2bar~600L/min 2.5bar | 4kW~260kW |
SUNDI -25℃~300℃ | 1kW~200kW | 2.5kW~200kW | 20L/min 2bar~600L/min 2.5bar | 4kW~260kW |
SUNDI -45℃~250℃ | 0.45kW~200kW | 3.5kW~200kW | 35L/min 2bar~600L/min 2.5bar | 6.5kW~280kW |
SUNDI -60℃~250℃ | 2.5kW~60kW | 0.25kW~60kW | 20L/min 2bar~250L/min 2.5bar | 5kW~95kW |
SUNDI -70℃~250℃ | 0.4kW~15kW | 2.5kW~15kW | 20L/min 2bar~110L/min 2.5bar | 5.2kW~28kW |
SUNDI -25℃~200℃ 1&2 | 1kW*2~10kW*2 | 2.5kW*2~10kW*2 | 20L*2/min 1.5bar~50L*2/min 2bar | 7.5kW~31kW |
SUNDI -40℃~250℃ 1&2 | 0.45kW*2~10kW*2 | 2.5kW*2~10kW*2 | 20L*2/min 1.5bar~60L*2/min 2bar | 8kW~33kW |
High &Low Temperature For Semiconductor Test
Model | Heating Power | Refrigerating Output | Temp. control Accuracy | Power | Circulation Pump |
TES -45℃~250℃ | 2.5kW~25kW | 0.25kW~25kW | ±0.3℃ | 6kW~36kW | 20L~150L/min2.5bar |
High &Low Temperaute For Vehicle Test
Model | Heating Power | Cooling Capacity | Temp. Control Accuracy | Power |
KRY -40℃~+100℃ | 5.5kW~38kW | 1.2kW~60kW | ±0.5℃ | 12kW~82kW |
KRY 0℃~+100℃ | 2.5kW~38kW | 1.8kW~60kW | ±0.5℃ | 6.5kW~50kW |
KRY -25℃~+100℃ | 5.5kW~25kW | 2.8kW~38kW | ±0.5℃ | 11kW~45kW |
You can contact us for custom temperature solutions. Just state your needs.
Plastic industry: accurately control the mold temperature of all kinds of plastic granulation, reduce the beer molding cycle time, and ensure the stability of product quality.
Electronic industry: stabilize the molecular formula of electronic components in the production line, improve the standard rate of electronic components, apply it to the field of ultrasonic cleaning, and reasonably avoid the damage caused by the evaporation and evaporation of expensive detergent.
Electroplating field: control the electroplating temperature, improve the relative density and smoothness of plated parts, reduce the electroplating cycle time, improve productivity and improve product quality.
Mechanical Engineering: control the working pressure and oil temperature of steam pressure system software, stabilize the water temperature and steam pressure, increase the service time of oil products, improve the high efficiency of lubrication of mechanical equipment and reduce wear.
Industrial production of Engineering Construction: provide chilled water for concrete, make the molecular formula of concrete suitable for the main purpose of engineering construction, and reasonably improve the strength and ductility of concrete.
Vacuum plating: control the temperature of vacuum coating machine to ensure the high quality of plated parts.
Chemical and Pharmaceutical industry: in the medical industry, the key is to control the temperature control of hair alcohol drugs. Pharmaceutical manufacturing enterprises should flexibly use the chiller equipment, effectively strengthen technological innovation on the basis of giving full play to its advantages, improve the cost performance of the chiller, and then better serve the projects in the pharmaceutical industry.
Laser industry: used in laser marking machines, laser engraving machines, laser welding machines, laser inkjet printers, laser cutting machines and other laser processing equipment to accurately control the temperature required by the laser equipment to ensure the normal operation of the laser equipment.
star products
LTS -80℃~80℃
LTS -80℃~80℃ Fluorinated liquid temperature control system AFor chip testing · Temperature Control Accuracy ±0.1℃ at -80℃~-50℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser A…
LTS -60℃~80℃
LTS -60℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -60℃~-30℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…
LTS -40℃~80℃
LTS -40℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -40℃~-10℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…
LTS -20℃~35℃
LTS -20℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -20℃~0℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank v…
WTD -70℃~+200℃
WTD -70℃~+200℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.5℃ · Heating Power 38kW~50kW · Cooling Capacity 11kW~50kW · Circulation Pump(Water-cooled) 250L/min 3bar · Power 110kW~120kW 380V 50HZ MAX · We…
WTD -45℃~+250℃
WTD -45℃~+250℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.3℃ · Heating Power 5.5kW · Cooling Capacity 1.5kW~5.5kW · Circulation Pump(Water-cooled) 25L/min 2.5bar Double · Refrigerant R404A · Types Air…
WTD -25℃~+300℃
WTD -25℃~+300℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.3℃ · Heating Power 2kW~7.5kW · Cooling Capacity 1kW~7.5kW · Circulation Pump(Water-cooled) 7.5L/min 2.5bar~25L/min 3bar · Refrigerant R404A/R23 …
HRT -45℃~+250℃
HRT -45℃~+250℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.5℃ · Heating Power 2.5kW~15kW · Cooling Capacity 0.25kW~15kW · Circulation Pump(Water-cooled) 20L/min~110L/H 2bar · Refrigerant R404A/R507C · Ty…
HR -25℃~+200℃
HR -25℃~+200℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.5℃ · Heating Power 2.5kW~15kW · Cooling Capacity 1kW~15kW · Circulation Pump(Water-cooled) 20L/min~110L/H 2bar · Refrigerant R404A/R507C · Types A…
SUNDI -40℃~+200℃
SUNDI -40℃~+200℃ PRODUCT ADVANTAGES · Material Temperature Control Accuracy ±1.0℃ · Heating Power 2.5kW~10*2kW · Cooling Capacity 0.45*2kW~10*2kW · Power 8kW~33kW · Refrigerant R404A/R507C, optional: R448A · Weight…
loading…
已经是到最后一篇内容了!