What factors are related to the cooling effect of a 50 ton chiller?
What factors are related to the cooling effect of a 50 ton chiller?
1. Insufficient refrigerant
Solution: It is necessary to supplement sufficient refrigerant and maintain a pressure of around 0.5MPa during refrigeration.
2. Due to climate reasons, the outdoor temperature is too high in summer, resulting in high condensation pressure and temperature during outdoor unit operation.
Solution: It is necessary to improve the operation of the outdoor unit or restart it after the ambient temperature is suitable.
3. The dust on the surface of the condenser is not cleaned for a long time, and the accumulated dust is too thick, which leads to poor heat dissipation effect and an increase in compressor exhaust pressure and temperature, resulting in a decrease in refrigeration capacity.
Solution: The surface area of the condenser needs to be cleaned of dust, and it should also be cleaned regularly.
4. Excessive refrigerant addition leads to excessive discharge pressure and temperature of the compressor
Solution: Release excess refrigerant and maintain its pressure at around 0.5MPa during refrigeration.
5. There is a leak in the refrigerant pipeline.
Solution: Use a leak detector to identify the refrigerant leak, repair it, and replenish the refrigerant to maintain its operating pressure at around 0.5MPa during refrigeration.
6. The indoor unit air filter screen is blocked.
Solution: Clean the air filter screen.
Related recommendations
What should I do if the temperature difference between the inlet and outlet of the water cooled industrial chiller is small?
405What should I do if the temperature difference between the inlet and outlet of the water cooled industrial chiller is small? Technicians stated that when users use water-cooled chillers...
View detailsHow to deal with excessive noise in air cooled water chiller?
412How to deal with excessive noise in air cooled water chiller? Excessive noise in air-cooled chillers may be caused by the following reasons: unreasonable unit design, equipment aging, c...
View detailsWhy does the lab water chiller compressor burn out?
416Why does the lab water chiller compressor burn out? 1. One of the reasons is that due to a lack of phase, prolonged use can lead to burnout. The refrigeration compressor has correspondi...
View detailsHow to reduce vibration and noise in air cooled water chiller system?
422How to reduce vibration and noise in air cooled water chiller system? 1. The on-site rotor dynamic balance method for air-cooled chiller compressors reduces direct current vibration. ...
View details
HelloPlease log in