TCU – LNEYA Thermal Test Chillers https://www.lneyathermal.com 丨Semiconductor Testing Chiller Manufacturer Tue, 18 Apr 2023 07:01:40 +0000 zh-Hans hourly 1 https://www.lneyathermal.com/wp-content/uploads/2022/10/cropped-Lneya-logo2-32x32.jpg TCU – LNEYA Thermal Test Chillers https://www.lneyathermal.com 32 32 ST 10℃~135℃ https://www.lneyathermal.com/product/hot-water-system-st.html https://www.lneyathermal.com/product/hot-water-system-st.html#respond Fri, 28 Oct 2022 08:44:34 +0000 https://www.lneyathermal.com/?p=1446

ST 10℃~135℃

PRODUCT ADVANTAGES

· Material Temperature Control Accuracy ±1.0℃

· Heating Power 25kW~300kW

· Circulation Pump 110L/min 2.5bar~600L/min 2.5bar

· Power 1.8kW~7.5kW

· Steam Pressure 4~6bar

Appearance Structure

Main Parameters

Model ST-25W ST-38W ST-60W ST-100W ST-200W ST-300W
Steam pressure 4~6bar
Hot water temperature range RT+10℃~135℃
Temperature control accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Heat exchange capacity max 25kw 38kw 60kw 100kw 200kw 300kw
Steam interface DN20 PN10 DN20 PN10 DN20 PN10 DN25 PN10 DN32 PN10 DN40 PN10
Pump flow 110L/min
2.5bar
200L/min 
2.5bar max
200L/min
2.5bar max
250L/min
2.5bar max
400L/min
2.5bar max
600L/min 2.5bar max
Hot water import and export DN25 PN10 DN32 PN10 DN40 PN10 DN50 PN10 DN80 PN10 DN80 PN10
Drain port size DN25 PN10 DN32 PN10 DN40 PN10 DN50 PN10 DN80 PN10 DN80 PN10
Control System PLC controller
Display and input 7-inch color touch screen,Temperature curve display, recording
Steam flow control Through proportional control valve,4~20mA signal adjustment opening size
power supply 380V50HZ 1.8kw 2.5kw 2.5kw 4kw 5.5kw 7.5kw
Dimensions 700*800*1750 700*800*1750 1000*950*1750 1250*1000*2000 1500*1250*2050 2050*1450*2050

Accessories Details

  1. Heat medium: saturated steam pressure: 0.5MPa and above, temperature: 158.8℃ and above
  2. Hot water control temperature RT +10℃~135℃
  3. Utilize steam to heat the process water by using a pipeline steam and water mixed heat exchanger
  4. Steam has low noise, no vibration and high thermal efficiency in the use of heat exchange process.
  5. The service life of the steam and water mixed heat exchanger is more than 15 years
  6. The process hot water temperature is constant, no need for manual duty, automatic control

Product Applications

In the process production of pharmaceutical and chemical enterprises, steam heating is required to achieve process heat preservation or to heat the process with hot water circulation.

Recommended ProductsUsed for Reaction

loading…

已经是到最后一篇内容了!

]]>
https://www.lneyathermal.com/product/hot-water-system-st.html/feed 0
SR -120℃~+250℃ https://www.lneyathermal.com/product/sr-120250.html https://www.lneyathermal.com/product/sr-120250.html#respond Fri, 28 Oct 2022 08:06:05 +0000 https://www.lneyathermal.com/?p=1441

SR -120℃~+250℃

PRODUCT ADVANTAGES

· Material Temperature Control Accuracy ±1.0℃

· Heating Power 25kW~80kW

· Circulation Pump 200L/min 2.5bar~750L/min 2.5bar

· Power 2.30kW~10.5kW

· Temperature Control Reactant temperature

· Heat Exchange Area 3.5㎡~20㎡

Appearance Structure

TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of process equipment or in the secondary loop.This achieves only one type of heat transfer liquid can flow into the jacket of the reaction vessel (not directly flow into steam, cooling water or ultra-low temperature liquid).The temperature of the whole reaction process is controlled by operation.

Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 °C ~ 350 °C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.

Main Parameters
Model SR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Temp. range ℃ -120~ 250°C setting the max temp according to the supplier heating or cooling source)
-40~135°C (The maximum temperature range can be operated by using glycol water formula.)
SR-N A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank.
SR-NS Besides SR- N function,add one set heater used to reduce high temp.
SR-NH Besides SR- N  function,add electrical heating function
SR-NSH Besides SR- N  function,add one set heater used to reduce high temp and electrical heating function
Expansion tank 100L 200L 280L 390L 500L
Heat exchanger area 3.5㎡ 5㎡ 8㎡ 12.5㎡ 20㎡
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temperature control selection Reactor material temperature control
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Material temp. feedback:PT100 or 4~20mA or communication given
Temp.feedback:PT100
Process temp. feedback
feedback:PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 200L/min 2.5BAR 250L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension cm 150*120*185 180*140*240 180*140*240 220*180*265 220*180*265
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material Cold-rolled sheet spraying (standard color 7035)
Accessories Details

Product Applications

Widely used in the research of production users such as petroleum, chemical industry, materials, pesticides, flavors and fragrances, medicine and various scientific research and experimental projects. It is used to complete the process of crystallization, hydrogenation, polymerization, condensation, heating and mixing, and constant temperature reaction.

Recommended ProductsUsed for Reaction

loading…

已经是到最后一篇内容了!

]]>
https://www.lneyathermal.com/product/sr-120250.html/feed 0
ZLF -45℃~+250℃ https://www.lneyathermal.com/product/zlf-45250.html https://www.lneyathermal.com/product/zlf-45250.html#respond Fri, 28 Oct 2022 07:44:45 +0000 https://www.lneyathermal.com/?p=1431

ZLF -45℃~+250℃

PRODUCT ADVANTAGES

· Material Temperature Control Accuracy ±1.0℃

· Heating Power 25kW~80kW

· Circulation Pump 150L/min 2.5bar~750L/min 2.5bar

· Power 2.30kW~10.5kW

· Temperature Control Reactant temperature

· Heat Exchange Area 3.5㎡~20㎡

Appearance Structure

Main Parameters
Model ZLF-35N
ZLF-35NS
ZLF-35NH
ZLF-35NSH
ZLF-50N
ZLF-50NS
ZLF-50NH
ZLF-50NSH
ZLF-80N
ZLF-80NS
ZLF-80NH
ZLF-80NSH
ZLF-125N
ZLF-125NS
ZLF-125NH
ZLF-125NSH
ZLF-200N
ZLF-200NS
ZLF-200NH
ZLF-200NSH
Temp. range ℃ -45~ 250°C (setting the max temp according to the supplier heating or cooling source)
-40~135°C(The maximum temperature range can be operated by using glycol water formula.)
ZLF-  N The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled.
ZLF-  NS Besides ZLF- N function,add one set heater used to reduce high temp.
ZLF-  NH Besides ZLF- N function,add electrical heating function
ZLF-  NSH Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temp control selection Reactor material temperature control
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Process temp. feedback Raw material process feedback:PT100 or 4~20mA or communication given
Temp. feedback:PT100
temp feedback: normal PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 150L/min 2.5BAR 200L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve piece Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension cm 150*120*185 180*120*210 180*120*210 225*120*240 225*120*240
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material Cold-rolled sheet spraying (standard color 7035)
 Accessories Details
Product Applications

Mainly used to provide cold and heat sources for reaction kettles, and is widely used in heating, cooling, heat preservation, crystallization, concentration, drying and other reactions in medicine, fine chemical industry and other fields.

Recommended ProductsUsed for Reaction

loading…

已经是到最后一篇内容了!

]]>
https://www.lneyathermal.com/product/zlf-45250.html/feed 0