Addition of refrigerant
During the use of air-cooled chillers, there may be insufficient or missing refrigerant due to various reasons (such as refrigerant leakage, maintenance, etc.). To ensure the normal operation of the air-cooled chiller unit, it is necessary to add refrigerant. The following is the method of adding refrigerant:
1. Safety inspection
Before adding refrigerant, it is important to conduct a safety check on the entire system. Firstly, check for cracks, leaks, etc. After inspection, determine the amount of refrigerant to be added based on the type of refrigerant used.
2. Material preparation
After determining the amount of refrigerant to be added, materials such as refrigerant, brass valves, and valve gaskets need to be prepared. Usually, refrigerants are sold in bottles or barrels, and it is necessary to confirm that the purchased refrigerant is the same model as the air cooled chiller you are using.
3. System emptying
Before adding refrigerant, it is necessary to evacuate the air and water in the system. This process can be achieved by connecting a vacuum pump, forced exhaust, and other means.
4. Add refrigerant
When adding refrigerant, it is necessary to first turn off the power supply of the air-cooled chiller, and then connect the refrigerant to the corresponding pipeline of the chiller. Usually, refrigerant is injected through two ports, high-pressure and low-pressure, and it needs to be connected correctly according to the pipeline connection method of the chiller. When adding refrigerant, it is necessary to gradually inject it to ensure that each addition of refrigerant only occupies 10-20% of the total amount of refrigerant in the cold water machine.
5. Inspection
After adding refrigerant, restart the air-cooled chiller after a period of time, and check it after 15 minutes of operation to confirm whether the system operates normally.
Related recommendations
What are the steps for stopping a small water chiller?
100What are the steps for stopping a small water chiller? Stop the small chiller and enter normal shutdown, emergency shutdown, automatic shutdown, and long-term shutdown stop modes. ...
View detailsAdvantages of laboratory low-temperature circulators
76Advantages of laboratory low-temperature circulators The laboratory low-temperature circulator can simultaneously provide constant temperature and current refrigeration, heating, and ...
View detailsWhy does the lab water chiller compressor burn out?
79Why does the lab water chiller compressor burn out? 1. One of the reasons is that due to a lack of phase, prolonged use can lead to burnout. The refrigeration compressor has correspondi...
View detailsWhat is the impact of the outlet temperature of the chilled water for a 100 ton chiller?
75What is the impact of the outlet temperature of the chilled water for a 100 ton chiller? We often talk about the cooling capacity of a 100 ton chiller. In fact, the nominal cooling capa...
View details
HelloPlease log in